BW Technologies MicroClip XT Manuál Strana 23

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 28
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 22
GasAlertMicroClip
Specifications
21
XT Model
XL Model
Specifications
Instrument dimensions:
XT: 11.25 x 6.00 x 2.89 cm (4.4 x 2.4 x 1.1 in.)
XL: 11.25 x 6.00 x 3.22 cm (4.4 x 2.4 x 1.2 in.)
Weight:
XT: 170 g (6.0 oz.)
XL: 190 g (6.7 oz.)
Operating temperature: -20°C to +50°C (-4°F to +122°F),
+50°C to +58°C is certified by CSA International on the
combustible sensor with ±5% accuracy
Storage temperature: -40°C to +50°C (-40°F to +122°F)
Operating humidity: 0% to 95% relative humidity
(non-condensing)
Alarm setpoints: May vary by region and are user defined. All
setpoints automatically display during the startup self-test.
Detection range:
H
2
S: 0 - 100 ppm (1 / 0.1 ppm increments)
CO: 0 - 500 ppm (1 ppm increments)
O
2
: 0 - 30.0% vol. (0.1% vol. increments)
Combustible (LEL): 0 - 100% (1% LEL increments) or
0 - 5.0% v/v methane
2
1
2
1
Zobrazit stránku 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28