BW Technologies MicroClip XT Specifikace Strana 61

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 74
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 60
GasAlertMicroClip XT
Technical Reference Guide
50
Table 13. Replacing a Sensor or Sensor Filter
1. Deactivate the detector. On a clean surface, place the
detector face down.
2. Remove the six machine screws on the rear shell.
3. Remove the back cover by lifting the top and the bottom
upwards simultaneously to prevent damaging the char-
ger pins.
Replacing the Sensor Filter
1. Note the placement of the PCB to ensure it is replaced
correctly. Remove the two screws on the PCB. Remove
the PCB carefully.
a Caution
Ensure no damage occurs to the battery.
2. Remove the old sensor filter. It may be stuck to the sen-
sors.
3. Insert the new sensor filter.
Note
When inserting a new sensor filter, ensure the black gasket is
facing the front shell.
4. To complete the detector, refer to Reassembling the
detector.
Replacing the H
2
S, CO, and LEL sensor
1. Note the placement of the PCB to ensure it is replaced
correctly. Remove the two screws on the PCB. Remove
the PCB carefully.
a Caution
Ensure no damage occurs to the battery.
If the sensor filter is stuck to the sensors, remove and replace the
sensor filter into the front shell.
2. Slide the sensors out.
Item Description
1 Front shell
2 Combustible (LEL) sensor
3PCB
4 PCB screws (2)
5 Rear shell
6 Machine screws (6)
7 Sealing rib
8 Carbon monoxide (CO) sensor
9
Hydrogen sulfide (H
2
S) sensor
10
Oxygen (O
2
) sensor
11 Sensor filter
Zobrazit stránku 60