GasAlertMicroClip
User Manual
If more than one type or level of alarm exists at the same
time, a multi-gas alarm will result.
Alarms
The following table describes the detector alarms and shows
how the LCD looks for each alarm.
To change the factory-set alarm setpoints, refer to the
GasAlertMicroClip Soft Tools instruction sheet.
During an alarm condition, the detector activates the
backlight, audible/visual/vibrator alarms, and the LCD shows
the current ambient gas reading.
Table 6. Alarms
Alarms Display` Alarms Display
Low Alarm:
Slow siren
Slow alternating flash
L and target gas bar flash
Vibrator alarm activates
High Alarm:
Fast siren
Fast alternating flash
L and target gas bar flash
Vibrator alarm activates
TWA Alarm:
Slow siren
Slow alternating flash
L and target gas bar flash
Vibrator alarm activates
STEL Alarm:
Fast siren
Fast alternating flash
L and target gas bar flash
Vibrator alarm activates
22